Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - c 428; e018 oil leakage was observed stbd da at disc coupling area near fly wheel suspect oil seal at pto end defective defect to be rectified and proved for leakage fre..
Tender For supply of supply and fixing of expansion valve required for ac plant of capacity 5.5 tr , supply and fixing of v belt size a-28, a-32 suitable for 11 by 5.5 tr package unit ac , supply and fixing of micro filter for ac plant of capacity 5.5 by 11 tr , supply and fixing of outdoor fan motor for package ac plant of capacity 5.5 tr , supply and fixing of repair fan blade of outdoor unit of ac plant of capacity 5.5 tr , supply and fixing of connector for 30 to 40 amps, 440 volts , supply and fixing of contactor suitable for ac plant of capacity 16.5 by 11 tr , supply and fixing of auto change over switch for package type ac plant 11 tr , supply and charging r-22 gas to maintain required cooling effect as and when required in the package type ac , supply and charging r-407 gas to maintain required cooling effect as and when required in the package type ac , supply and charging nitrogen gas for finding out leakage as and when required as specified and directed by engr in charge , supply and fixing of microprocessor by printed circuit board with ct coil suitable for 11 tr package type ac plant , supply and fixing replacement of capacitor 10 mfd , supply and fixing of temperature display controller unit for 16.5 by 11 tr , cleaning of evaporator coils of ac plant of capacity 5.5 tr with dilute hcl by force feed method to remove the dust particles formed on coil and fins , servicing incl cleaning of condenser cooling coil, refrigerant coils fins with mild detergent and descaling of condenser coil for package type 5.5 tr ac , servicing incl cleaning of condenser cooling coil, refrigerant coils fins with mild detergent and descaling of condenser coil for package type 11 tr ac , disconnecting, dismantling and taking out existing burnt out compressor of package type ac 5.5 tr capacity and supply and fixing sealed unit compressor of existing capacity, single phase 230v ac , disconnecting, dismantling and taking out existing burnt out compressor of package type ac 11 tr capacity and supply and fixing sealed unit compressor of existing capacity, single phase 230v ac
Tender For providing of custom bid for services - servicing of 12 inch rolling mills,custom bid for services - arresting oil leakage from 12 inch rolling mill,custom bid for services - servicing of von rolling mill
Tender For supply of protection relay for motor, part no.mlprm100 , insulators complete set, part no.mlpins101 , pt fuse f 6.6kv 7.2kv,3.15a, part no.mlptfs102 , lt fuse link , 10 a, part no.mlpltfss106 , ammeter , analogue, 96 sq mm, part no.mlpaa111 , aux contactor w 3no 1nc w 110v coil, part no.mlpac116 , push button actuator with 1 no 1nc, part no.mlpbovsne127 , aux switch with 2 no 2 nc, part no.mlpas132 , aux switch with 3 no 3 nc, part no.mlpas133 , relay tove phs falur prvntn,w u and o vltg, part no.mlppr145 , numerical overcurrent relay, part no.mlpnor181 , auxiliary transformer prim 110 220v, part no.mlpat209 , ammeter selector switch, part no.mlpass108 , voltmeter selector switch, part no.mlpvss109 , vcum intrptr asmbly,7.2kv,400a,110v coil, part no.mlpsrab135 , ht fuse , 125 amp 6.6 kv , power fuse, part no.mlpht103 , copper busbar,50 6,10mtrs, part no.mlpcbm158 , relay earth leakage cbt 2.5 to110v, part no.mlpcbt149 , delay timer electronic 0 to 30 s , part no.mlpbch210
Tender For corrigendum : replacement/repairing of clutch assy., poor racing, diesel leakage , gear-box repairing and hydraulic cylinder leakage repairing of vehicle no. up64 at/5004(diesel-tanker) of make tata at bina project.
Tender For bed tr leakage observation of u/s spillway and l/s wing wall as per cdo suggestions of bed tr near village bed in jamnagar taluka of jamnagar district.
Tender For sound proofing work providing and fixing soundproofing partition using 50 mm gl framework with double layer gypsum boards on both sides. 100 mm thick high density rockwool insulation shall be placed inside the framework for effecitive sound absorption and noise reduction. all joints and edges will be properly sealed to minimize sound leakage. the proposed sound proofing system will reduce noise levels from approximately 100-110 db to 50-5 db